• Title of article

    Influence of injection site, microvascular pressureand ultrasound variables on microbubble-mediated delivery of microspheres to muscle

  • Author/Authors

    Ji Song، نويسنده , , John C. Chappell، نويسنده , , Ming Qi، نويسنده , , Eric J. VanGieson، نويسنده , , Sanjiv Kaul، نويسنده , , Richard J. Price، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2002
  • Pages
    6
  • From page
    726
  • To page
    731
  • Abstract
    Objectives Our objective was to test the hypothesis that the ultrasound pulsing interval (PI), microbubble injection site and microvascular pressure significantly influence the transport of 100-nm microspheres to muscle through extravasation sites created by the destruction of microbubbles with ultrasound. Background Microbubbles show promise as targeted drug and gene delivery agents; however, designing optimal microbubble-based therapies will require an understanding of the factors that influence the transport of microbubble-delivered, gene-bearing vehicles to tissue. Methods Ultrasound at 1 MHz, with a peak negative pressure amplitude of 0.75 MPa, was applied to microbubbles and 100-nm microspheres in exteriorized rat spinotrapezius muscle. Ultrasound PIs of 1, 3, 5 and 10 s, arterial microsphere injection times of 10 or 40 s and arterial versus venous injection sites were tested. Results Extravasation point creation and microsphere delivery were greatest when the ultrasound PI was 5 or 10 s. No significant differences in extravasation point creation or microsphere delivery were observed with arterial versus venous microbubble injection, but a trend toward increased microsphere delivery with arterial injection may exist. Decreasing the arterial injection time from 40 to 10 s increased microvascular pressure, which, in turn, substantially enhanced microsphere transport to tissue, without a concomitant increase in the number of extravasation points. Conclusions The ultrasound PI and microvascular pressure significantly influence the creation of extravasation points and the transport of microspheres to tissue. These factors may be important in designing and optimizing contrast ultrasound-based therapies.
  • Keywords
    MI , mechanical index , PI , pulsing interval , PM , polymer microsphere , VEGF , vascular endothelial growth factor , VEGF
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Serial Year
    2002
  • Journal title
    JACC (Journal of the American College of Cardiology)
  • Record number

    597123