Title of article :
Quantitative assessment of coronary stenosis by harmonic power Doppler with a simple pulsing sequence and vasodilator stress in patients
Author/Authors :
Yuichiro Takagi، نويسنده , , Koji Ohmori، نويسنده , , Kazushi Yukiiri، نويسنده , , Isao Kondo، نويسنده , , Yang Yu، نويسنده , , Akira Oshita، نويسنده , , Hiroto Takeuchi، نويسنده , , Katsufumi Mizushige*، نويسنده , , Masakazu Kohno، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Pages :
8
From page :
2060
To page :
2067
Abstract :
Objectives We examined whether myocardial contrast echocardiography (MCE) with harmonic power Doppler (HPD) employing a simple ultrasound pulsing sequence enables estimation of the severity of coronary artery stenosis in patients. Background Contrast intensity (CI) during MCE with intravenous microbubble infusion is dependent on the myocardial blood flow velocity (MBFV) and pulsing interval (PI). Methods Based on an in vitro experiment, we devised the MBFV index calculated as the reciprocal of the magnitude of CI decay produced by abrupt PI shortening during intermittent imaging. In 68 coronary artery territories from 49 patients, myocardial HPD images were acquired during intravenous infusion of Levovist, while the long PI with 1:10 electrocardiographic gating was shortened to 1:1, both at baseline and during adenosine triphosphate infusion. The MBFV index in each coronary territory and MBFV reserve as the ratio between hyperemia and baseline were compared with the severity of corresponding coronary artery stenosis assessed by quantitative coronary angiography (QCA) or by pressure guide wire as the fractional flow reserve (FFR). Results Both the MCE-derived MBFV index during hyperemia and MBFV reserve exhibited significant negative correlations with the QCA-derived stenosis severity (r = −0.56 and r = −0.64, respectively). The MBFV reserve positively correlated with FFR (r = 0.89). By combining the cutoff values of the MBFV index during hyperemia and MBFV reserve, ≥75% of stenoses defined by QCA were determined, with a sensitivity of 77.3%, specificity of 93.4%, and accuracy of 88.3%. Conclusions Shortening of PI during intravenous MCE with intermittent HPD imaging under vasodilator stress enables assessment of coronary artery stenoses in patients.
Keywords :
CI , PI , contrast intensity , pulsing interval , ECG , QCA , electrocardiographic , or electrocardiographically , FFR , fractional flow reserve , HPD , harmonic power Doppler , LAD , left anterior descending coronary artery , myocardial blood flow (velocity) , ATP , MCE , adenosine triphosphate , myocardial contrast echocardiography , MBF(V) , Electrocardiogram , quantitative coronary angiography
Journal title :
JACC (Journal of the American College of Cardiology)
Serial Year :
2003
Journal title :
JACC (Journal of the American College of Cardiology)
Record number :