• Title of article

    Sizing for modified david’s reimplantation procedure

  • Author/Authors

    Lars G Svensson، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    3
  • From page
    1751
  • To page
    1753
  • Abstract
    The problem of sizing the graft, annulus, and left ventricular outflow tract for the David reimplantation type of aortic valve preserving procedure remains a concern, particularly in patients with Marfan syndrome. To resolve this issue, a modified method used in over 20 patients is described of doing the repair around a Hegar’s dilator. In essence, the size chosen is according to the patient’s normalized annular size based on body surface area. This technique also creates a neosinus in the root.
  • Journal title
    The Annals of Thoracic Surgery
  • Serial Year
    2003
  • Journal title
    The Annals of Thoracic Surgery
  • Record number

    607086