Title of article :
Monitoring weaning from BIVAD thoratec with peak oxygen consumption
Author/Authors :
Pascal H. Colson، نويسنده , , Frederique Ryckwaert، نويسنده , , Max Saussine، نويسنده , , Marc Ferrière، نويسنده , , Bernard Albat، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
3
From page :
1808
To page :
1810
Abstract :
A biventricular assistance device has been implanted in a young woman for a peripartum cardiac failure. An intended weaning consisted of gradual reloading and exercise training monitored with peak oxygen consumption (V 2) and radionuclide-left ventricle ejection fraction. Progressive increase in peak V 2during partial assistance occurred more than 2 months, from 10.3 to 19 mL • kg−1 • min−1. Successful explantation was realized when peak V 2 exceeded 15 mL • kg−1 • min−1 and radionuclide-left ventricle ejection fraction was more than 40% during off-pump testing.
Journal title :
The Annals of Thoracic Surgery
Serial Year :
2004
Journal title :
The Annals of Thoracic Surgery
Record number :
607568
Link To Document :
بازگشت