• Title of article

    Reinforcement of Saphenous Vein Graft With ePTFE Graft for Axillocoronary Bypass Grafting

  • Author/Authors

    Hiroyuki Nagahama، نويسنده , , Yasunori Fukushima، نويسنده , , Takahiro Hayase، نويسنده , , Makoto Yoshioka، نويسنده , , Toshio Onitsuka، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    2
  • From page
    700
  • To page
    701
  • Abstract
    Arteriosclerosis in the ascending aorta is widely accepted as a strong risk factor for the occurrence of stroke after coronary artery bypass grafting (CABG). The aortic no-touch technique, with a variety of modifications, has been used to reduce the risk of post-CABG stroke. Saphenous vein grafts (SVGs) have been used for axillocoronary bypass grafting, a modification of the aortic no-touch technique. However, kinking or compression often occurs with SVGs. We report here the successful application of an 8-mm expanded polytetrafluoroethylene graft, of the external bead support type, that was used to cover an SVG during axillocoronary bypass grafting.
  • Journal title
    The Annals of Thoracic Surgery
  • Serial Year
    2005
  • Journal title
    The Annals of Thoracic Surgery
  • Record number

    608353