• Title of article

    Sutureless Repair With TachoComb Sheets for Oozing Type Postinfarction Cardiac Rupture

  • Author/Authors

    Akihito Muto، نويسنده , , Toshiya Nishibe، نويسنده , , Yuka Kondo، نويسنده , , Masato Sato، نويسنده , , Mituru Yamashita، نويسنده , , Motomi Ando، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    3
  • From page
    2143
  • To page
    2145
  • Abstract
    Left ventricular free-wall rupture is a well recognized complication of myocardial infarction and a frequent cause of death. The appropriate surgical management varies significantly depending on the condition of the tear and the presence of concomitant lesions. We present a case of oozing type postinfarction cardiac rupture that was treated successfully by a sutureless patch technique using a fibrin tissue-adhesive collagen fleece (TachoComb [Torii Pharmaceutical, Tokyo, Japan]). This represents a quick, effective, and safe option for dealing with oozing type myocardial rupture due to myocardial infarction.
  • Journal title
    The Annals of Thoracic Surgery
  • Serial Year
    2005
  • Journal title
    The Annals of Thoracic Surgery
  • Record number

    608696