Prosthesis-Patient Mismatch After Aortic Valve Replacement: Impact of Age and Body Size on Late Survival
Author/Authors :
Marc R. Moon، نويسنده , , Michael K. Pasque، نويسنده , , Nabil A. Munfakh، نويسنده , , Spencer J. Melby، نويسنده , , Jennifer S. Lawton، نويسنده , , Nader Moazami، نويسنده , , John E. Codd، نويسنده , , Traves D. Crabtree، نويسنده , , Hendrick B. Barner، نويسنده , , Ralph J. Damiano Jr، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
9
From page :
481
To page :
489
Abstract :
Background The purpose of this study was to identify patient subgroups in which prosthesis-patient mismatch most influenced late survival. Methods Over a 12-year period, 1,400 consecutive patients underwent bioprosthetic (933 patients) or mechanical (467) aortic valve replacement. Prosthesis-patient mismatch was defined as prosthetic effective orifice area/body surface area less than 0.75 cm2/m2 and was present with 11% mechanical and 51% bioprosthetic valves. Results With bioprosthetic valves, prosthesis-patient mismatch was associated with impaired survival for patients less than 60 years old (10-year: 68% ± 7% mismatch versus 75% ± 7% no mismatch, p< 0.02) but not older patients (p= 0.47). Similarly, with mechanical valves, prosthesis-patient mismatch was associated with impaired survival for patients less than 60 years old (10-year: 62% ± 11% versus 79% ± 4%, p< 0.005) but not older patients (p = 0.26). For small patients (body surface area less than 1.7 m2), prosthesis-patient mismatch did not impact survival with bioprosthetic (p = 0.32) or mechanical (p= 0.71) valves. For average-size patients (body surface area 1.7 to 2.1 m2), prosthesis-patient mismatch was associated with impaired survival with both bioprosthetic (p< 0.05) and mechanical (p< 0.005) valves. For large patients (body surface area greater than 2.1 m2), prosthesis-patient mismatch was associated with impaired survival with mechanical (p< 0.04) but not bioprosthetic (p= 0.40) valves. Conclusions Prosthesis-patient mismatch had a negative impact on survival for young patients, but its impact on older patients was minimal. In addition, although prosthesis-patient mismatch was not important in small patients, prosthesis-patient mismatch negatively impacted survival for average-size patients and for large patients with mechanical valves.
Journal title :
The Annals of Thoracic Surgery
Serial Year :
2006
Journal title :
The Annals of Thoracic Surgery
Record number :
609371
Link To Document :
بازگشت