Title of article
Preoperative Determination of Artificial Chordae Length
Author/Authors
Mohammad Hossein Mandegar، نويسنده , , Mohammad Ali Yousefnia، نويسنده , , Farideh Roshanali، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
3
From page
680
To page
682
Abstract
We present a practical and accurate way to measure artificial chordae length in mitral valve repair. During preoperative transesophageal echocardiography, the distance between the head of the posterior papillary muscle and the mitral annulus plane at the coaptation of the leaflets is measured; this is the length of the new chorda. Every millimeter of braided 4-0 Gore-Tex (W.L. Gore & Assoc, Flagstaff, AZ) contains two tight reverse knots; therefore, the number of the knots determines the accurate length of the artificial chorda.
Journal title
The Annals of Thoracic Surgery
Serial Year
2007
Journal title
The Annals of Thoracic Surgery
Record number
610924
Link To Document