Title of article :
Self-Expandable Covered Metal Tracheal Type Stent for Sealing Cervical Anastomotic Leak After Esophagectomy and Gastric Pull-Up: Pitfalls and Possibilities
Author/Authors :
Joerg Lindenmann، نويسنده , , Veronika Matzi، نويسنده , , Christian Porubsky، نويسنده , , Udo Anegg، نويسنده , , Oliver Sankin، نويسنده , , Sabine Gabor، نويسنده , , Nicole Neuboeck، نويسنده , , Alfred Maier، نويسنده , , Freyja Maria Smolle-Juettner، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
3
From page :
354
To page :
356
Abstract :
From January 2003 to June 2006, 6 patients with leakage of the cervical esophagogastrostomy after esophagectomy and gastric pull-up underwent endoscopic stenting using the self-expandable covered tracheal type device. Anastomotic healing was satisfactory. Stent extraction was performed after an average interval of 91 days. Initial stent migration occurred in 2 patients and post-extraction stenosis developed in 3 patients. Insertion of a self-expandable covered metal tracheal stent represents a safe approach resulting in immediate closure and subsequent healing of cervical anastomotic leakage.
Journal title :
The Annals of Thoracic Surgery