Title of article :
Hemolytic Anemia After Operation for Aortic Dissection Using Teflon Felt Strips
Author/Authors :
Yuki Nakamura، نويسنده , , Hitoshi Ogino، نويسنده , , Hitoshi Matsuda، نويسنده , , Kenji Minatoya، نويسنده , , Hiroaki Sasaki، نويسنده , , Soichiro Kitamura، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
4
From page :
1784
To page :
1787
Abstract :
We report three cases of hemolytic anemia caused by anastomotic stenosis after surgical treatment for aortic dissection in which internal and external Teflon (DuPont, Wilmington, DE) felt strips were used for reinforcement of the aortic stump. To detect this complication, laboratory findings typical of red cell fragmentation syndrome as well as appropriate imaging modalities are necessary. As a precaution, it is necessary to be meticulous when stitching the internal felt strip.
Journal title :
The Annals of Thoracic Surgery
Serial Year :
2008
Journal title :
The Annals of Thoracic Surgery
Record number :
611616
Link To Document :
بازگشت