• Title of article

    True Aneurysmal Dilatation of a Contegra Conduit after Right Ventricular Outflow Tract Reconstruction: A Novel Mechanism of Conduit Failure

  • Author/Authors

    Victor Bautista-Hernandez، نويسنده , , Aditya K. Kaza، نويسنده , , Oscar J. Benavidez، نويسنده , , Frank A. Pigula، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    2
  • From page
    1976
  • To page
    1977
  • Abstract
    Valved conduits are frequently used in congenital heart surgery to establish continuity between the right ventricle and the pulmonary arteries. The Contegra bovine jugular vein (Medtronic Inc, Minneapolis, MN) is a conduit that incorporates a tri-leaflet valve and affords off-the-shelf availability, good handling characteristics, and excellent hemodynamics. However, complications related to the use of this device have been reported, with conduit failure occurring mainly as a consequence of stenosis, conduit thrombosis, and valve regurgitation. We present a case of aneurysmal conduit failure of a 14-mm Contegra conduit used to reconstruct the right ventricular outflow tract.
  • Journal title
    The Annals of Thoracic Surgery
  • Serial Year
    2008
  • Journal title
    The Annals of Thoracic Surgery
  • Record number

    612111