• Title of article

    Intraoperative monitoring of IMA flow: What does it mean?

  • Author/Authors

    Ofer Barnea، نويسنده , , William P. Santamore، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1997
  • Pages
    6
  • From page
    12
  • To page
    17
  • Abstract
    Background. This study examines whether the measurement of internal thoracic artery (ITA) graft flow can determine the adequacy of the ITA-left anterior descending coronary artery (LAD) anastomosis. Methods. To study a wide range of clinical problems, we used a computer simulation of the cardiovascular system. The model included a time-varying elastance model of the heart, a systemic circulation represented by a multielement nonlinear model of the aorta and its major branches, a nonlinear model of the LAD circulation, and a model of the ITA bypass graft. Results. With a mild LAD stenosis, ITA graft flow was low and flow reversal occurred. As the percent stenosis increased, ITA flow and the percentage of ITA-to-total LAD flow increased. The ITA graft helped to maintain resting LAD blood flow. A partial obstruction (40%) at the ITA—LAD anastomosis reduced ITA graft flow at similar levels of LAD stenosis. However, overlap in flow values comparing a normal with a partially obstructed anastomosis occurred. Conclusions. Flow patterns in the ITA are highly dependent on the degree of stenosis of the LAD as well as the integrity of the anastomosis. The predictive power of ITA flow measurement increases with severe stenosis or total occlusion of the proximal LAD and with high coronary blood flow demands.
  • Journal title
    The Annals of Thoracic Surgery
  • Serial Year
    1997
  • Journal title
    The Annals of Thoracic Surgery
  • Record number

    614273