Title of article
Intravalvular implantation technique for aortic valve replacement in aortitis syndrome
Author/Authors
Yutaka Kotsuka، نويسنده , , Osamu Tanaka، نويسنده , , Shinichi Takamoto، نويسنده , , Akira Furuse، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1999
Pages
4
From page
89
To page
92
Abstract
Background. Paravalvular leakage is one of the most serious complications of aortic valve replacement in patients with aortitis syndrome. The purpose of this study was to compare the effectiveness of the intravalvular implantation technique in preventing paravalvular leakage with that of the conventional technique.
Methods. Since 1982, 14 patients with aortic regurgitation caused by aortitis syndrome have undergone aortic valve replacement at our institute. An intravalvular implantation technique was applied in 7 of the 14 patients. The technique consists of suturing a prosthetic valve to the aortic annulus and sandwiching the leaflets between exogenous felt pledgets and the inflamed aortic annulus.
Results. Paravalvular leakage occurred in 3 of 7 patients in the conventionally treated group and in none of 7 in the intravalvular implantation group.
Conclusions. The intravalvular implantation technique is effective in preventing paravalvular leakage in patients with aortitis syndrome.
Journal title
The Annals of Thoracic Surgery
Serial Year
1999
Journal title
The Annals of Thoracic Surgery
Record number
615625
Link To Document