• Title of article

    Intravalvular implantation technique for aortic valve replacement in aortitis syndrome

  • Author/Authors

    Yutaka Kotsuka، نويسنده , , Osamu Tanaka، نويسنده , , Shinichi Takamoto، نويسنده , , Akira Furuse، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 1999
  • Pages
    4
  • From page
    89
  • To page
    92
  • Abstract
    Background. Paravalvular leakage is one of the most serious complications of aortic valve replacement in patients with aortitis syndrome. The purpose of this study was to compare the effectiveness of the intravalvular implantation technique in preventing paravalvular leakage with that of the conventional technique. Methods. Since 1982, 14 patients with aortic regurgitation caused by aortitis syndrome have undergone aortic valve replacement at our institute. An intravalvular implantation technique was applied in 7 of the 14 patients. The technique consists of suturing a prosthetic valve to the aortic annulus and sandwiching the leaflets between exogenous felt pledgets and the inflamed aortic annulus. Results. Paravalvular leakage occurred in 3 of 7 patients in the conventionally treated group and in none of 7 in the intravalvular implantation group. Conclusions. The intravalvular implantation technique is effective in preventing paravalvular leakage in patients with aortitis syndrome.
  • Journal title
    The Annals of Thoracic Surgery
  • Serial Year
    1999
  • Journal title
    The Annals of Thoracic Surgery
  • Record number

    615625