Title of article :
Computed axial tomography–MIBI image fusion for preoperative localization in primary hyperparathyroidism
Author/Authors :
Christoph Profanter، نويسنده , , Rupert Prommegger، نويسنده , , Michael Gabriel، نويسنده , , Roy Moncayo، نويسنده , , Gerold J. Wetscher، نويسنده , , Thomas Lang، نويسنده , , Reto Bale، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Pages :
5
From page :
383
To page :
387
Abstract :
Background An imaging-guided unilateral surgical approach in patients with primary hyperparathyroidism (HPTH) requires reliable preoperative localization procedures. Using present imaging techniques, 60% to 80% of patients with primary HPTH can be treated successfully with limited surgery. Thus, further improvement of diagnostic accuracy is required. Computed axial tomography (CAT)–MIBI image fusion was introduced as a new technique for localizing enlarged parathyroid glands. We describe the new method and present its first results. Methods Six consecutive patients with primary HPTH underwent CAT–MIBI image fusion for preoperative parathyroid localization. CAT and technetium-99m–sestamibi scan were performed separately. The patientʹs head and neck were fixed with the noninvasive Vogele-Bale-Hohner Head Holder (VBH HeadFIX; Medical Intelligence, Schwabmünchen, Germany) and the BodyFIX (Medical Intelligence) vacuum cushion. Radiographic and scintigraphic markers were mounted at the head holder and the patient. CAT and MIBI images were fused by overlaying radiographic markers using a commercial software and workstation. Results In 5 patients, localization and dimension of the solitary adenomas were exactly predicted. In 1 patient with multiglandular disease (3 enlarged glands), CAT–MIBI image fusion was not able to predict multiple gland involvement. However, in a retrospective analysis of the localization study, the other two enlarged parathyroid glands could be correctly identified regarding their site and size. Conclusions First results of CAT–MIBI image fusion are promising. The new technique provides a higher image resolution and better delimitation of enlarged parathyroid glands and adjacent anatomic structures than conventional scintigraphic methods.
Keywords :
Computed axial tomography–MIBI image fusion , primary hyperparathyroidism , Preoperative parathyroid localization
Journal title :
The American Journal of Surgery
Serial Year :
2004
Journal title :
The American Journal of Surgery
Record number :
617499
Link To Document :
بازگشت