Title of article :
An alternative linear stapling technique for performing Roux-en-Y anastomosis
Author/Authors :
Marcel Autran C. Machado، نويسنده , , Paulo Herman، نويسنده , , André L. Montagnini، نويسنده , , Rony Eshkenazy، نويسنده , , Danton Spohr Corrêa، نويسنده , , Marcel C. C. Machado، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Pages :
3
From page :
449
To page :
451
Abstract :
Background: The use of stapling devices for performing gastrointestinal anastomosis has gained wide acceptance in the last decade. Linear cutting devices have been used routinely during gastrointestinal operations in our hospital since 1992. However, we still have shortage of stapling devices due to cost reduction politics. Methods We propose a modification of the standard technique in order to reduce the number of devices used. Our technique employs a single stapled including the section of the jejunum and the side-to-side jejunoanastomosis. Results We have used this technique for 1 year without complications related to the stapled anastomosis. Conclusions This technique may reduce the time of reconstruction of Roux-en-Y anastomosis without interfering in its final result. This modified technique may be useful in hospitals with reduced economic resources.
Keywords :
Roux-en-Y , Anastomosis , Surgical stapling
Journal title :
The American Journal of Surgery
Serial Year :
2002
Journal title :
The American Journal of Surgery
Record number :
621531
Link To Document :
بازگشت