Title of article :
Application of a sinusoidal internal model to current control of three-phase utility-interface converters
Author/Authors :
S.، Fukuda, نويسنده , , R.، Imamura, نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Pages :
-41
From page :
42
To page :
0
Abstract :
Three-phase voltage-source converters are used as utility interfaces. In such a case, the converter line currents are required to track sinusoidal references synchronized with the utility grid without a steady-state error. In this paper a current control method based on a sinusoidal internal model is employed. The method uses a sine transfer function with a specified resonant frequency, which is called an S regulator. The combination of a conventional proportional-integral (PI) regulator and an S regulator is called a PIS regulator. The PIS regulator ensures that the steady-state error in response to any step changes in a reference signal at the resonant frequency and 0 Hz reduces to zero. An experiment was carried out using a 1-kVA prototype of three utility-interface converters, a voltage-source rectifier, an active power filter, and static synchronous compensator. Almost perfect currenttracking performance could be observed.
Keywords :
Bacillus subtilis , (alpha)-Amylase , histidine modification , enzyme purification , hydrolytic enzyme , Thermophilic bacteria
Journal title :
IEEE Transactions on Industrial Electronics
Serial Year :
2005
Journal title :
IEEE Transactions on Industrial Electronics
Record number :
62451
Link To Document :
بازگشت