• Title of article

    Limitation of the load angle in a direct-torque-controlled synchronous machine drive

  • Author/Authors

    J.، Luukko, نويسنده , , O.، Pyrhonen, نويسنده , , M.، Niemela, نويسنده , , J.، Pyrhonen, نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2004
  • Pages
    -792
  • From page
    793
  • To page
    0
  • Abstract
    The basic direct torque control (DTC) principle is to rotate the flux linkage forward, if the torque must be increased, and reverse, if the torque must be decreased. The torque is, however, increased only up to a maximum torque of the machine, which corresponds to a load angle of about 90/spl deg/ in a synchronous machine. This paper presents a method to overcome the possible loss of synchronism when using DTC. This requires either that the rotor angle is measured or estimated. Both of these cases are considered. Simulation and laboratory results are presented to show the effectiveness of the presented method.
  • Journal title
    IEEE Transactions on Industrial Electronics
  • Serial Year
    2004
  • Journal title
    IEEE Transactions on Industrial Electronics
  • Record number

    62585