Title of article
Problems associated with the direct torque control of an interior permanent-magnet synchronous motor drive and their remedies
Author/Authors
M.F.، Rahman, نويسنده , , Md.E.، Haque, نويسنده , , Tang، Lixin نويسنده , , Zhong، Limin نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
-798
From page
799
To page
0
Abstract
This paper investigates problems associated with the implementation of a direct torque control (DTC) strategy for an interior permanent-magnet synchronous motor drive. The DTC technique is increasingly drawing attention because of elimination of current controllers and, hence, their inherent delays, and elimination of the rotor position sensor. The latter advantage perhaps is the main impetus for considering this new approach of torque control. Problems associated with this controller, namely, the offset in the current measurements, the stator resistance variation, and the requirement of initial rotor position are addressed in this paper. Ways of mitigating of these problems are also investigated in this paper. These are evaluated with modeling and experimental studies, results of which are also presented.
Journal title
IEEE Transactions on Industrial Electronics
Serial Year
2004
Journal title
IEEE Transactions on Industrial Electronics
Record number
62587
Link To Document