Title of article :
Acute maternal hydration in third-trimester oligohydramnios: Effects on amniotic fluid volume, uteroplacental perfusion, and fetal blood flow and urine output
Author/Authors :
Nicola J. Flack، نويسنده , , Waldo Sepulveda، نويسنده , , Sarah Bower، نويسنده , , Nicholas M. Fisk، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 1996
Pages :
6
From page :
1186
To page :
1191
Abstract :
OBJECTIVE: Our purpose was to determine whether acute maternal hydration in pregnancies with third-trimester oligohydramnios (1) increases amniotic fluid index and hourly fetal urine production rate and (2) alters uteroplacental perfusion and fetal blood flow. STUDY DESIGN: Ten women with third-trimester oligohydramnios (amniotic fluid index ≤5 cm) and 10 controls with normal amniotic fluid volume (amniotic fluid index>7 cm) were prospectively recruited for this study. Maternal plasma and urine osmolality, amniotic fluid index, hourly fetal urine production rate, and Doppler flow velocimetry of maternal uterine artery and fetal umbilical, descending aorta, middle cerebral, and renal arteries were determined before and after oral hydration by having the patient drink 2 L of water over 2 hours. RESULTS: There was a significant reduction in maternal plasma (p< 0.05) and urine osmolality (p< 0.0001) in both groups after short-term oral hydration. Hydration increased amniotic fluid volume in women with oligohydramnios (mean change in amniotic fluid index 3.2 cm, 95% confidence intervals 1.1 to 5.3; p< 0.02) but not in those with normal amniotic fluid volume (mean change in amniotic fluid index −2.0, 95% confidence intervals −4.1 to +0.2). The hourly fetal urine production rate, however, did not increase in either group (mean change in hourly fetal urine production rate 3.5 ml/hr, 95% confidence intervals −11.7 to +18.7 and −6.8 ml/hr, 95% confidence intervals −2.9 to −10.7, respectively). Hydration was associated with an increased in uterine artery mean velocity in the oligohydramnios group (mean change in mean velocity 16.7 cm/sec, 95% confidence intervals 8.0 to 25.3; p< 0.006) but not in controls (mean change in mean velocity 1.2 cm/sec, 95% confidence intervals −19.7 to +22.1). There was no change in pulsatility index or in velocity in any of the fetal vessels studied in either group. CONCLUSIONS: Short-term maternal oral hydration increases the amniotic fluid index in women with third-trimester oligohydramnios. Although the mechanism for this effect remains unclear, it could not be accounted for by fetal urination in this study but instead was associated with improved uteroplacental perfusion.
Keywords :
color Dopplerultrasonography , Oligohydramnios , maternal oral hydration , amniotic fluid volume
Journal title :
American Journal of Obstetrics and Gynecology
Serial Year :
1996
Journal title :
American Journal of Obstetrics and Gynecology
Record number :
639174
Link To Document :
بازگشت