Title of article :
Balloon dilation of neonatal critical aortic valvar stenosis via the umbilical artery
Author/Authors :
Podnar، Tomaz نويسنده , , Berden، Pavel نويسنده , , Vesel، Samo نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2009
Abstract :
To report our experience with balloon dilation of critical aortic valvar stenosis in neonates
via the umbilical artery using currently available catheters. Background: There is no agreement regarding the
optimal vascular approach for balloon dilation of critical aortic valvar stenosis in neonates. Methods: Since June
of 2005, we have attempted to obtain umbilical arterial access within the first week after birth in all neonates
with critical aortic valvar stenosis. In patients in whom umbilical artery access was obtained, we proceeded
with an attempt at balloon dilation. Results: We were presented with 5 patients with critical aortic valvar
stenosis within the first week after birth, and the umbilical arterial approach was obtained in all, with effective
relief of the stenosis achieved in 4. Conclusions: The umbilical arterial approach should always be considered
for balloon dilation of neonatal critical aortic valvar stenosis. Using currently available catheters, the procedure
is safe, simple, and effective even in patients weighing less than 2.5 kilograms. Further experience using this
approach is warranted.
Keywords :
Catheterization , Congenital Heart Disease , Aortic valve
Journal title :
Cardiology in the Young
Journal title :
Cardiology in the Young