Title of article
In vitro Comparative Study of Compressive Strength of Different Types of Composite Resins in Different Periods of Time
Author/Authors
Sepideh Banava، نويسنده , , Saman Salehyar، نويسنده ,
Issue Information
فصلنامه با شماره پیاپی سال 2008
Pages
6
From page
69
To page
74
Abstract
To evaluate the ultimate compressive strength of five composite resins after 1 hour, 24 hours, 7 days and 1 month. Twenty four cylindrical 4 mm×8mm specimens of each commonly used composite resins in posterior region (Nulite-F , Z250 , P60, Biscore, Tetric ceram HB) were prepared. Each group of composite resins were divided into four time groups of 1 h, 24 h, 7 days and 1 month. All of specimens stored in an incubator with 37 °C. After each period of time all of the specimens were tested by Zwick/Roell Z020 (Germany) for ultimate compressive strength at cross head speed of 0.5 cm/min. Results were analyzed by ANOVAand Scheffe test. P60 and Z250 had the highest and Nulite-F and Tetric ceram HB had the lowest compressive strength at all the times. The difference between these two groups was statistically significant (p<0.05). The results of the Biscore was steady among the other groups. It is suggested to use Z250 or P60 in posterior restorations instead of the other composite resins tested.
Keywords
Fiber reinforced composite resins , composite resins , Compressive strength