Title of article :
Potentiometric PVC Membrane Sensor for the Determination of Phenylephrine Hydrochloride in Some Pharmaceutical Products
Author/Authors :
M. Giahi، نويسنده , , M. Mirzaei and G. Veghar Lahijani، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2010
Pages :
6
From page :
333
To page :
338
Abstract :
A new PVC membrane electrode for the determination of phenylephrine hydrochloride based on the formation of an ionassociation complex of phenylephrine hydrochloride with the phosphotungstate counter anion as an electroactive material dispersed in a PVC matrix is described. The sensor shows a fast, stable, near-Nernstian response for 1.0 × 10-5 to 1.0 × 10-1 M phenylephrine hydrochloride at 25 °C over the pH range of 3.5-8.0 with a cationic slope of 58.1 ± 0.6 mV decade-1. The electrode was successfully used for potentiometric determination of phenylephrine hydrochloride in some pharmaceutical drugs
Keywords :
PVC-membrane , Potentiometry , Selectivity , Ion-pair sensor , Phenylephrine hydrochloride
Journal title :
Journal of the Iranian Chemical Society (JICS)
Serial Year :
2010
Journal title :
Journal of the Iranian Chemical Society (JICS)
Record number :
666936
Link To Document :
بازگشت