Title of article :
Voltammetric Determination of Vitamin B6 (Pyridoxine) Using Multi Wall Carbon Nanotube Modified Carbon-Ceramic Electrode
Author/Authors :
M. B. Habibi Najafi1 and A. Moatamedzadegan1، نويسنده , , H. Phezhhan and M.H. Pournaghi-Azar، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2010
Pages :
10
From page :
103
To page :
112
Abstract :
A simple procedure was developed to prepare a carbon-ceramic electrode (CCE) modified with multi wall carbon nanotube (MWCNT). The electrochemical behavior of pyridoxine was investigated on the obtained electrode in phosphate buffer solution (PBS), pH 7.0. During oxidation of pyridoxine on the MWCNT/CCE, one irreversible anodic peak at Ep = 716 mV vs. SCE appeared. Cyclic voltammetric study indicated that the oxidation process is irreversible and diffusion controlled. The number of exchanged electrons in the electro-oxidation process was obtained, and the data indicated that pyridoxine is oxidized via two oneelectron steps. The results revealed that MWCNT promotes the rate of oxidation by increasing the peak current, so that pyridoxine is oxidized at lower potentials, which thermodynamically is more favorable compared with on the bare CCE. A sensitive, simple and time-saving differential pulse voltammetric procedure was developed for the analysis of pyridoxine. Using the proposed method, pyridoxine can be determined with a detection limit of 95 nM. The applicability of the method to direct assays of some commercial pharmaceutical samples is described
Keywords :
Vitamin B6 , Pyridoxine , Voltammetric detection , Carbon-ceramic electrode , Multi wall carbon nanotube
Journal title :
Journal of the Iranian Chemical Society (JICS)
Serial Year :
2010
Journal title :
Journal of the Iranian Chemical Society (JICS)
Record number :
667026
Link To Document :
بازگشت