Title of article :
Efficacy of the FreshLighf 220 Ultraviolet Light System for Control and Elimination of Naturally Occurring Microflora and Listeria innocua in a Formulated Poultry Marinade (Flow Rate = 40 GPM and Turnover Time 1 = minute)
Author/Authors :
K.W. Beers، نويسنده , , J.W. Rheingans andA.L. Waldroup، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Abstract :
Due to the recirculation process used in poultry injection procedures, the potential hazard of a buildup of naturally occurring organisms and potential pathogens in recirculated marinade poses a concern to the poultry industry. Thus, a study was designed to investigate the possibility of alleviating this problem. A typical poultry marinade (40 gallons) was formulated in the laboratory in accordance with the manufacturerʹs instructions using chicken powder, sodium chloride and sodium phosphate dissolved in potable water. A sample of the marinade solution was collected and microbiologically evaluated using Aerobic Plate Count Petrifilm™3 to determine an initial bacterial count. The marinade solution was then allowed to circulate in a FreshL/g/7i® 220 ultraviolet light system (Safe Foods Corporation, N. Little Rock, AR) for 1 minute (flow rate = 40 gallons per minute and solution turnover time = 1 minute) to determine microbial reductions in the naturally occurring microflora. The initial microbial count of the marinade was 3.6 logs per mL (colony forming units). After 1 minute of ultraviolet light treatment, the level of naturally occurring microflora was reduced to 1 log representing a 99.7% reduction. The marinade solution was then inoculated with an overnight culture of Listeria innocua to achieve a total level of bacteria in the marinade of 5.0 logs per mL. The inoculated marinade was then treated with the FreshL/g/7/11 220 ultraviolet light system for a period of 30 minutes. A sample of the marinade solution was collected every minute during the 30-minute test period and was plated on Aerobic Plate Count Petrifilm™3 to determine bacterial reductions over time. After only 1 minute (1 pass through the system), the total level of organisms in the marinade solution was reduced by 1.5 logs, after 5 minutes (5 passes) by > 3 logs, and by 9 minutes (9 passes) by > 4 logs indicating no recovery of organisms (the lower detection level was 1 log per mL). There was no recovery of organisms at any further treatment time. Thus, in less than 10 minutes of ultraviolet light treatment, the FreshL/g/7/11 220 ultraviolet light system was capable of achieving a 4 log reduction in total organisms (primarily Listeria innocua) in the poultry marinade solution. This represents a 99.99% reduction. In conclusion, the commercially available FreshL/g/7/11 220 ultraviolet light system (FDA regulated under 21 CFR 179.39) provides the processor with a very cost effective means of controlling and eliminating the incidence and levels of Listeria innocua in poultry marinades.
Keywords :
Poultry , food safety , marinades , Listeria innocua , Fresh Lighf
Journal title :
International Journal of Poultry Science
Journal title :
International Journal of Poultry Science