Abstract
Transformers must be monitored continuously
and damaging discharge must be detected reliably too.
Three important types of Partial Discharge (PD) defects
that may occur in high voltage equipment are corona,
surface discharges and discharges in the insulation
cavities. These three signals are different in some
attributes. In this paper we are looking for properties that
are significant and distinguishing in comparison. Three
different strategies will be used for achieving admissible
results. It must be noted that for denoising, the wavelet
functions will be used, based on two methods [2, 3].