Title of article :
Influence of Fasteners Disposition on Behaviour of Timber-Framed Walls with Double Fibre-Plaster Coating Boards
Author/Authors :
P. Carlson-Kuhta، نويسنده , , M.Premrov، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
6
From page :
1
To page :
6
Abstract :
This paper provides experimental analysis of timber-framed walls, coated with double fibre-plaster coating boards fastened to the timber frame. As the walls under a horizontal load actually behave like a deep composite beam, the fasteners disposition is very important and directly influences bearing capacity and stiffness of the wall. Therefore, three different groups of test samples with staple distances of s = 37.5, 75 and 150 mm were experimentally analysed and compared. For groups G2 and G3 the failure of FPB occurred. It has been shown that proposed simplified Eurocode 5 methods, applicable for wood-based sheathing board might be unsuitable for the problems presented.
Keywords :
Structures , Walls , Fibre-plaster boards , Fasteners , Experiments
Journal title :
American Journal of Applied Sciences
Serial Year :
2008
Journal title :
American Journal of Applied Sciences
Record number :
688305
Link To Document :
بازگشت