• Title of article

    The prediction of PCDD/DF levels in wet scrubbers associated with waste incinerators Original Research Article

  • Author/Authors

    Ki-In Choi، نويسنده , , Dong-Hoon Lee، نويسنده , , Masahiro Osako، نويسنده , , Sam-Cwan Kim، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    7
  • From page
    1131
  • To page
    1137
  • Abstract
    Wet scrubber is one of the most conventional types of air pollutant control devices (APCDs), which is specially designed to treat dust and acidic gases in the flue gas simultaneously. In spite of its outstanding ability to control them, however, wet scrubbers have been considered as potential contaminant sources that may increase PCDD/DF concentrations in the flue gas. In this study, we investigated the change of PCDD/DF concentrations at the inlets and outlets of seven wet scrubbers, and compared them with other published data. With a multi-regression analysis of dust concentrations and temperature at the inlets and outlets of given wet scrubbers, we developed an empirical model to understand factors dominating the change of PCDD/DF concentrations. As a result, we confirmed that the changes of PCDD/DF concentrations in wet scrubbers are closely related to their concentrations at the inlets, which would usually be determined by the type of APCDs installed upstream of the wet scrubber.
  • Keywords
    Wet scrubber , memory effect , PCDD/DF
  • Journal title
    Chemosphere
  • Serial Year
    2007
  • Journal title
    Chemosphere
  • Record number