Title of article
Quantification of ecotoxicological tests based on bioluminescence using Polaroid film Original Research Article
Author/Authors
Manu V. Tamminen، نويسنده , , Marko P.J. Virta، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
7
From page
1329
To page
1335
Abstract
Assays based on the measurement of bacterial luminescence are widely used in ecotoxicology. Bacterial strains responding either to general toxicity or specific pollutants are rapid, cost-effective and easy to use. However, quantification of the signal requires relatively expensive instrumentation. We show here that the detection of luminescence of BioToxTM, a Vibrio fischeri-based toxicity test, and of a specific recombinant bacterial strain for arsenic determination, is possible using common Polaroid film. The exposed films can be used for visual or computer-assisted quantification of the signal. Qualitative visual comparison to standards can be used in the rapid and relatively accurate estimation of toxicity or pollutant concentration. The computer-assisted method significantly improves the accuracy and quantification of the results. The results obtained by computer-assisted quantification were in good agreement with the values obtained with a luminometer.
Keywords
Toxicity testing , arsenic , Bioreporter , ground water , Environmental analysis , drinking water
Journal title
Chemosphere
Serial Year
2007
Journal title
Chemosphere
Record number
724651
Link To Document