Title of article :
Investigation of arsenic removal in batch wise water treatments by means of sequential hydride generation flow injection analysis Original Research Article
Author/Authors :
Kei Toda، نويسنده , , Mari Takaki، نويسنده , , Md. Abul Hashem، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
7
From page :
1517
To page :
1523
Abstract :
Arsenic water pollution is a big issue worldwide. Determination of inorganic arsenic in each oxidation state is important because As(III) is much more toxic than As(V). An automated arsenic measurement system was developed based on complete vaporization of As by a sequential procedure and collection/preconcentration of the vaporized AsH3, which was subsequently measured by a flow analysis. The automated sensitive method was applied to monitoring As(III) and As(V) concentrations in contaminated water standing overnight. Behaviors of arsenics were investigated in different conditions, and unique time dependence profiles were obtained. For example, in the standing of anaerobic water samples, the As(III) concentration immediately began decreasing whereas dead time was observed in the removal of As(V). In normal groundwater conditions, most arsenic was removed from the water simply by standing overnight. To obtain more effective removal, the addition of oxidants and use of steel wools were investigated. Simple batch wise treatments of arsenic contaminated water were demonstrated, and detail of the transitional changes in As(III) and As(V) were investigated.
Keywords :
ArsenicWater analysisSequential hydride generation flowinjection analysis (SHGFIA)Batch treatment of water for arsenicremovalDetermination of arsenite and arsenate
Journal title :
Chemosphere
Serial Year :
2008
Journal title :
Chemosphere
Record number :
726332
Link To Document :
بازگشت