Title of article :
A Side-by-Side Comparison of Sampling Methods for Settled, Indoor Allergens
Author/Authors :
Mona Mansour، نويسنده , , Bruce P. Lanphear، نويسنده , , Richard Hornung، نويسنده , , Jane Khoury، نويسنده , , David I. Bernstein، نويسنده , , William Menrath، نويسنده , , Joji Decolongon، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Pages :
10
From page :
37
To page :
46
Abstract :
Exposure to indoor allergens is associated with asthma, but there is no standardized sampling method for measuring allergens. We compared the association of measured allergen exposure and serum-specific IgE levels and the precision of three sampling methods (Cyclone, Mighty Mite, and Readivac II) to identify a standardized sampling method for indoor allergens. A random sample of 72 children, 5 to 17 years old, with doctor-diagnosed asthma who lived in the same residence ≥2 years were enrolled. Composite, side by side floor samples were obtained with all three methods. Dust allergen concentrations and serum-specific IgE levels were measured for Der f I, Fel d I, and Bla g I. Mean allergen concentration did not differ significantly by sampling method. Cat allergen was significantly correlated with serum-specific IgE for Cyclone (P=0.003) and Mighty Mite (P=0.008), but only marginally for Readivac II (P=0.07). Dust mite allergen was significantly correlated with serum-specific IgE for Readivac II (P=0.02) and Cyclone (P=0.038), but not for Mighty Mite (P=0.12). Cockroach allergen was not correlated with serum-specific IgE for any sampling method. In multiple linear regression, cat allergen was associated with serum-specific IgE for Cyclone (P=0.007) and Mighty Mite (P=0.02), but not for Readivac II (P=0.06). In contrast, dust mite allergen was marginally associated with serum-specific IgE for Readivac II (P=0.07), but not for Mighty Mite (P=0.64) or Cyclone (P=0.27). The Cyclone and Mighty Mite were more precise than Readivac II for cat allergen, but there was no difference for dust mite allergen (P>0.05). No single method is superior for measurement of indoor allergens. In general, cat allergen collected with the Cyclone was a better predictor of serum-specific IgE levels to Fel d I, whereas dust mite allergen collected with the Readivac II was a better predictor of serum-specific IgE levels to Der f I.
Keywords :
environment , pediatrics , dust , sampling , IgE , children , indoor allergens , asthma
Journal title :
Environmental Research
Serial Year :
2001
Journal title :
Environmental Research
Record number :
727832
Link To Document :
بازگشت