Title of article
PCDDs/DFs emissions from crematories in Japan
Author/Authors
Nobuo Takeda، نويسنده , , Masaki Takaoka، نويسنده , , Takeshi Fujiwara، نويسنده , , Hisayuki Takeyama، نويسنده , , Shoji Eguchi، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2000
Pages
12
From page
575
To page
586
Abstract
Concentrations of PCDDs and PCDFs in emission gases from 10 crematories were measured. The relationship between PCDDs/DFs and several factors such as structure, equipment and operational state of the crematory is discussed. Furthermore, emission of PCDDs/DFs from all crematories in Japan is estimated. The following results are obtained: (1) total concentration of PCDDs/DFs was 2.2–290 ng/N m3, whose TEQ concentration was 0.0099–6.5 ng TEQ/N m3; (2) total concentration of PCDFs was higher than that of PCDDs; (3) T4CDFs was the highest in the homologue pattern and 2,3,7,8-T4CDF was the highest in the isomer pattern; (4) emission of PCDDs/DFs was the largest in the first 20 min of cremation; (5) concentration of PCDDs/DFs was related to the existence of a secondary combustion chamber and a dust collector, and the ratio of the numbers of main and secondary combustion chambers; (6) total emission of PCDDs/DFs from crematories in Japan was estimated to be 8.9 g TEQ/yr.
Keywords
PCDDs/DFs , Crematory , Emission gas , Combustion , Gas sampling
Journal title
Chemosphere
Serial Year
2000
Journal title
Chemosphere
Record number
734925
Link To Document