Title of article :
Chromium (III) recovery from waste acid solution by ion exchange processing using Amberlite IR-120 resin: batch and continuous ion exchange modelling
Author/Authors :
Francisco José Alguacil، نويسنده , , Manuel Alonso، نويسنده , , Luis Javier Lozano، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2004
Abstract :
The use of ion exchange technology was studied to remove chromium (III) from acidic waste solution by Amberlite IR-120 resin. Batch and column experimental tests were conducted to provide data for theoretical models and verify the system performance of the adsorption process. Results of batch equilibrium tests indicated that Langmuir isotherm describes well the adsorption process, whereas experimental data also provide evidence that, under the present experimental conditions, chromium (III) adsorption by Amberlite IR-120 resin is film-diffusion controlled; on the other hand, the theoretical model used in the present investigation was found to predict reasonably well the ion exchange breakthrough performance.
Keywords :
Chromium (III) adsorption , Amberlite IR-120 , Batch and column operations
Journal title :
Chemosphere
Journal title :
Chemosphere