Title of article :
Dioxin emissions after installation of a polishing wet scrubber in a hazardous waste incineration facility
Author/Authors :
Carl-Johan L?thgren، نويسنده , , Bert van Bavel، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Pages :
8
From page :
405
To page :
412
Abstract :
Dioxin levels measured after wet scrubbing systems have been found to be higher than levels measured before the scrubber. It is believed that there is an adsorption of PCDD/Fs on plastic materials in the scrubber. The PCDD/F levels after a polishing wet scrubber were followed continuously for 18 months using long-time sampling equipment at a hazardous waste incineration facility in Sweden. Each sampling period lasted two weeks. It was found that the levels during and shortly after start-up periods were elevated. The decline was very slowly, which supports a memory effect in the scrubber. Further, a multivariate model showed that the relation between different homologues changed over time, which is in agreement with a desorption model, taking into account the vapour pressures for different congeners.
Keywords :
PCDD/PCDF , memory effect , Flue gas cleaning , MVDA , Incineration
Journal title :
Chemosphere
Serial Year :
2005
Journal title :
Chemosphere
Record number :
738273
Link To Document :
بازگشت