Title of article :
Characteristics of the collection efficiency for a double inlet cyclone with clean air
Author/Authors :
K. S. Lim، نويسنده , , S. B. Kwon، نويسنده , , K. W. Lee، نويسنده ,
Issue Information :
ماهنامه با شماره پیاپی سال 2003
Pages :
11
From page :
1085
To page :
1095
Abstract :
Two single inlet cyclones and a double inlet cyclone were designed and fabricated to evaluate, and compare, their collection efficiencies. Two single inlet cyclones had different inlet sizes and vortex finder diameters. The double inlet cyclone had two inlet parts that divided the cyclone inlet in two. Clean air was introduced to the inlet near the cyclone wall, and particle-laden air was introduced to the inlet away from the cyclone wall. This double inlet made the clean air swirl in the region near the vortex finder, and the particle-laden air swirl in the region close to cyclone wall. The performance of the double inlet cyclone was evaluated at various clean air flow rates, keeping the particle-laden air flow rate constant. The collection efficiency of the double inlet cyclone was found to be 5–15% greater than that of the single inlet cyclone with the same inlet size and vortex finder diameter. As the flow rate of clean air was increased, the collection efficiency increased. This result indicates the possibility of achieving higher collection efficiencies with a double inlet cyclone.
Keywords :
Double inlet cyclone , Collection e!ciency , clean air , Vortex finder
Journal title :
Journal of Aerosol Science
Serial Year :
2003
Journal title :
Journal of Aerosol Science
Record number :
742767
Link To Document :
بازگشت