Title of article
An improved low-flow thermodenuder
Author/Authors
Martin Fierz، نويسنده , , Martine G.C. Vernooij، نويسنده , , Heinz Burtscher، نويسنده ,
Issue Information
ماهنامه با شماره پیاپی سال 2007
Pages
6
From page
1163
To page
1168
Abstract
Thermodenuders are used to remove the volatile fraction of an aerosol. All designs until now have a cooled adsorption section where the volatile material is trapped, but theoretical considerations suggest that the adsorption section should be heated. Therefore, we built a thermodenuder with a heated adsorption section. We tested its performance with respect to particle penetration and its ability to remove DEHS coated onto NaCl nuclei. The measured losses are lower than in previously published designs and the DEHS removal appears to be satisfactory. Additionally, the new thermodenuder is practical for field use thanks to its small size. It should therefore be a good alternative to previous designs.
Keywords
Volatility , Thermodenuder
Journal title
Journal of Aerosol Science
Serial Year
2007
Journal title
Journal of Aerosol Science
Record number
743267
Link To Document