Title of article
Field trials of the TEOM® and Partisol for PM10 monitoring in the St Austell china clay area, Cornwall, UK
Author/Authors
L. F. Salter، نويسنده , , B. Parsons، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1998
Pages
4
From page
2111
To page
2114
Abstract
A comparison of particulate matter monitoring using a 1400a series TEOM and a 2000 series Partisol is reported for an area where airborne particulate matter content is dominated by geological material. A non-linear relationship (Partisol=0.6989TEOM1.179, R=0.961, n=100) was found to give the best description of the relationship between these two instruments. Some comparison data for the MINIVOL are also reported.
Keywords
Particulate monitoring , Partisol , TEOM
Journal title
Atmospheric Environment
Serial Year
1998
Journal title
Atmospheric Environment
Record number
755528
Link To Document