Title of article :
Winter comparison of TEOM, MiniVol and DustTrak PM10 monitors in a woodsmoke environment
Author/Authors :
Simon Kingham، نويسنده , , Michael Durand، نويسنده , , Teresa Aberkane، نويسنده , , Justin Harrison، نويسنده , , J. Gaines Wilson، نويسنده , , Michael Epton، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
10
From page :
338
To page :
347
Abstract :
This paper compares PM10 mass concentrations data generated by three co-located particulate monitors, the tapered element oscillating microbalance (TEOM40) (operating at 40 °C), MiniVol and DustTrak, operating outdoors during winter woodsmoke air pollution (Christchurch, New Zealand). TEOM40 data were adjusted to adjTEOM40 with an algorithm derived from a co-located TEOM40 and HiVol at a second field site. Corrected and corrected-loge-transformed data were analyzed with reduced major axis regression. Logged adjTEOM40 and DustTrak data correlated best (r2=0.81) but the DustTrak required a substantial correction factor to make data comparable in real terms. Consistent over-recording by the DustTrak and under-recording by the TEOM40 were consistent with previously published work. The MiniVol did not correlate well with other instruments (r2=0.62 and 0.53 against the adjTEOM40 and DustTrak, respectively) but reasons for this cannot be ascertained.
Keywords :
air pollution , monitoring networks , ambient monitoring , particulate matter
Journal title :
Atmospheric Environment
Serial Year :
2006
Journal title :
Atmospheric Environment
Record number :
759308
Link To Document :
بازگشت