  • Abstract
    Two pilot-scale hybrid water treatment systems using two different poly-vinylidene fluoride (PVDF) microfiltration (MF) membranes (i.e. symmetric and composite) were operated at a constant permeate flux of 104.2 l m−2 h−1 (=2.5 md−1) with a pre-coagulation/sedimentation, sand filtration (SF), and chlorination to produce potable water from surface water. Turbidity was removed completely. And humic substances, Al, and Fe were removed very well by the pilot-scale membrane system. To control microbial growth and mitigate membrane fouling, a NaOCl solution was injected into the effluent from SF before reaching the two membranes (pre-chlorination). However, it adversly affected membrane fouling due to the oxidization and adsorption of inorganic substances such as Al, Fe, and Mn. In the next run, the NaOCl was introduced during backwash (post-chlorination). As compared with the result of pre-chlorination, this change increased the operating period of the symmetric and the composite membranes from about 10 and 50 days to about 60 and 200 days, respectively.
  • Keywords
    Poly-vinylidene fluoride (PVDF)membranesSymmetric and compositePre-coagulation/sedimentationSand filtrationPre-chlorinationOxidization and adsorption ofinorganic substancesPost-chlorination
  • Journal title
    Water Research
  • Serial Year
    2008
  • Journal title
    Water Research
  • Record number

    764876