Title of article :
Membrane properties change in fine-pore aeration diffusers: Full-scale variations of transfer efficiency and headloss
Author/Authors :
Diego Rosso، نويسنده , , Judy A. Libra، نويسنده , , Wolfgang Wiehe، نويسنده , , Michael K. Stenstrom، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Abstract :
Fine-pore diffusers are the most common aeration system in municipal wastewater treatment. Punched polymeric membranes are often used in fine-pore aeration due to their advantageous initial performance. These membranes are subject to fouling and scaling, resulting in increased headloss and reduced oxygen transfer efficiency, both contributing to increased plant energy costs. This paper describes and discusses the change in material properties for polymeric fine-pore diffusers, comparing new and used membranes. Three different diffuser technologies were tested and sample diffusers from two wastewater treatment facilities were analysed. The polymeric membranes analysed in this paper were composed of ethylene–propylene-diene monomer (EPDM), polyurethane, and silicon. Transfer efficiency is usually lower with longer times in operation, as older, dilated orifices produce larger bubbles, which are unfavourable to mass transfer. At the same time, headloss increases with time in operation, since membranes increase in rigidity and hardness, and fouling and scaling phenomena occur at the orifice opening. Change in polymer properties and laboratory test results correlate with the decrease in oxygen transfer efficiency.
Keywords :
AerationDynamic wet pressureFine-pore diffuserHeadlossMembraneOxygen transfer efficiency
Journal title :
Water Research
Journal title :
Water Research