Title of article :
Investigation of microbial inactivation efficiency of a UV disinfection system employing an excimer lamp
Author/Authors :
Zorana Naunovic، نويسنده , , Soojung Lim، نويسنده , , Ernest R. Blatchley III، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
9
From page :
4838
To page :
4846
Abstract :
An ultraviolet (UV) disinfection reactor based on excimer lamp technology was designed by integration of the results of numerical simulations based on computational fluid dynamics and a fluence rate (E′) distribution model for cylindrical excimer lamps. The E′ distribution model was developed based on a point source approach that accounts for absorption, dissipation, reflection, and refraction within the reactor system. A prototype reactor was constructed with a xenon–bromide excimer lamp and an internal spiral baffle. Experiments were conducted on the reactor to test its effectiveness for disinfection of drinking water in situations where the use of mercury-based UV sources is restricted or undesirable; a similar design approach could be used to develop an excimer UV reactor for disinfection of other fluid media, including wastewater or air.
Keywords :
Fluence rate distributionExcimer lampXeBr*Ultraviolet (UV) disinfection
Journal title :
Water Research
Serial Year :
2008
Journal title :
Water Research
Record number :
765158