Abstract
The effects of freezing, acidification, refrigeration and extended storage without refrigeration on measured concentrations of forms of nitrogen and phosphorus were assessed in water samples taken from polluted and unpolluted streams in dry and wet weather. Emphasis was placed on likely changes associated with the use of automatic samplers in field conditions. The response of measured nutrient concentrations to different preservation methods and to extended storage without preservation varied widely between samples. For polluted streams where nutrient concentrations were high (ammoniacal nitrogen >0.1 mg l−1; oxidised nitrogen, total Kjeldahl nitrogen, total and filterable phosphorus >1 mg l−1), there was generally little proportional change in nutrients other than ammoniacal nitrogen after up to 6 d of storage without preservation. Where nutrient concentrations were low, up to 90% of ammoniacal nitrogen, 50% of oxidised nitrogen, 84% of total Kjeldahl nitrogen and 67% of total phosphorus was lost after 6 d. If samples cannot be retrieved immediately, automatic samplers should be refrigerated where possible. Acidification is a suitable alternative for preservation of nitrogen. Samples for filterable phosphorus should be filtered as soon as possible after collection. In some circumstances, unpreserved samples may provide an acceptable level of accuracy for evaluation of broad temporal trends or estimation of nutrient loadings.
Keywords
water quality , storage. phosphorus , preservation , nitrogen , autosampling
Journal title
Water Research
Serial Year
1998
Journal title
Water Research
Record number
766741
Link To Document