Title of article
Removal of THM precursors by GAC: Ankara case study
Author/Authors
G?ksen Caparand، نويسنده , , Ulkü Yets ، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2002
Pages
6
From page
1379
To page
1384
Abstract
The effectiveness of granular activated carbon (GAC) adsorption for the removal of natural organic matter and trihalomethanes from vedik Water Treatment Plant of Ankara City is investigated. Freundlich Isotherm constants K and n were determined as 17.61 and 1.66, respectively. Bench-scale GAC columns were run with empty bed contact times (EBCT) varying from 0.40 to 2.67 min to evaluate adsorption performance. 50% exhaustion values were used for comparison. The treated volumes of water increased with EBCT, showing a linear increase in GAC service life. Correspondingly, the carbon usage rate decreased. The capacities calculated by the isotherm equation and achieved by columns were also compared. The column capacities were within 43–65% of the isotherm capacities at complete breakthrough. However, they were only within 8–17% of the isotherm capacities at 50% breakthrough.
Keywords
GAC , trihalomethanes , adsorption , natural organic matter