Title of article
Removal of saxitoxins from drinking water by granular activated carbon, ozone and hydrogen peroxide—implications for compliance with the Australian drinking water guidelines
Author/Authors
Philip T. Orr، نويسنده , , Gary J. Jones، نويسنده , , Geoffrey R. Hamilton، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
7
From page
4455
To page
4461
Abstract
In a laboratory-scale trial, we studied the removal of saxitoxins from water by ozone, granular activated carbon (GAC) and H2O2, and considered the implications of residual toxicity for compliance with the Australian drinking water standards. Cell-free extracts of Anabaena circinalis were added to raw, untreated drinking water obtained from a water supply reservoir to provide a toxicity of 30 μg (STX equivalents) l−1. Ozone alone, or in combination with H2O2, failed to destroy the highly toxic STX and GTX-2/3, and only partially destroyed dc-STX, and the low-toxicity C-toxins and GTX-5. In all cases, the toxicity of the water was reduced by less than 10%. GAC removed all of the STX, dc-STX and GTXs, but only partially removed the C-toxins. However, the residual toxicity was reduced to the suggested Australian drinking water guideline concentration of 3 μg (STX equivalents) l−1 without O3 pre-treatment. Modelling the spontaneous chemical degradation of residual C-toxins following treatment shows that residual toxicity could increase to 10 μg l−1 after 11 d due to formation of dc-GTXs and would then gradually decay. In all, residual toxicity would exceed the Australian drinking water guideline concentration for a total of 50 d.
Keywords
Anabaena circinalis , toxin , Pre-column oxidation , HPLC , cyanobacteria , Paralytic shellfish poisons
Journal title
Water Research
Serial Year
2004
Journal title
Water Research
Record number
769249
Link To Document