• Title of article

    Ultrasonic control of ceramic membrane fouling: Effect of particle characteristics

  • Author/Authors

    Dong Chen، نويسنده , , Linda K. Weavers، نويسنده , , Harold W. Walker، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2006
  • Pages
    11
  • From page
    840
  • To page
    850
  • Abstract
    In this study, the effect of particle characteristics on the ultrasonic control of membrane fouling was investigated. Ultrasound at 20 kHz was applied to a cross-flow filtration system with γ-alumina membranes in the presence of colloidal silica particles. Experimental results indicated that particle concentration affected the ability of ultrasound to control membrane fouling, with less effective control of fouling at higher particle concentrations. Measurements of sound wave intensity and images of the cavitation region indicated that particles induced additional cavitation bubbles near the ultrasonic source, which resulted in less turbulence reaching the membrane surface and subsequently less effective control of fouling. When silica particles were modified to be hydrophobic, greater inducement of cavitation bubbles near the ultrasonic source occurred for a fixed concentration, also resulting in less effective control of fouling. Particle size influenced the cleaning ability of ultrasound, with better permeate recovery observed with larger particles. Particle size did not affect sound wave intensity, suggesting that the more effective control of fouling by large particles was due to greater lift and cross-flow drag forces on larger particles compared to smaller particles.
  • Keywords
    UltrasoundMembrane cleaningMembrane foulingLuminolCavitation
  • Journal title
    Water Research
  • Serial Year
    2006
  • Journal title
    Water Research
  • Record number

    772841