Title of article
Use of Fourier transform infrared spectrometry as a continuous emission monitor
Author/Authors
Zhuoxiong Mao، نويسنده , , Jack Demirgian، نويسنده , , Alex Mathew، نويسنده , , Richard Hyre، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 1995
Pages
11
From page
567
To page
577
Abstract
This paper describes the use of a Fourier transfer infrared (FTIR) spectrometer, integrated with a sampling system and a control software, as a continuous emission monitor (CEM) for on-line measurement of most volatile organic and some inorganic compounds from various gas emissions. The time response of the system was tested experimentally, and can be approximated by a complete mixing model. In order to validate the measurement accuracy of the system, spiking tests are suggested. This paper discusses considerations in designing the spiking test and analyzing the spiking results. Field test results show that the FTIR-CEM has a stable performance and can be applied to stack emission monitoring, process monitoring, and unknown HAPs identification in many thermal treatment processes.
Journal title
Waste Management
Serial Year
1995
Journal title
Waste Management
Record number
774171
Link To Document