• Title of article

    Development and evaluation of a mass spectrometer-based continuous emission monitor for volatile organic compound emmissions from combustion devices

  • Author/Authors

    E. T. Wada، نويسنده , , A. M. Sterling، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2001
  • Pages
    6
  • From page
    477
  • To page
    482
  • Abstract
    A mass spectrometer-based continuous emission monitor (MS-CEM) for organic compound emissions from combustion devices was developed and evaluated at the Louisiana State University (LSU) pilot-scale rotary kiln ncinerator (RKI). The MS-CEM consists of a stack probe, heat-traced sampling line, vacuum pump, particulate filter, Nafion@ dryer and mass spectrometer. The mass spectrometer includes a computer that controls and optimizes the operation of the unit. The MS-CEM is capable of continuously analyzing up to 40 different volatile organic compounds on a real-time basis. The MS-CEM is capable of analyzing, computing and recording the analytical results for each and up to 40 different organic compounds in less than 0.3 s. Four different volatile organic compounds were mixed together and injected into the baghouse inlet while simultaneously analyzing each organic component exiting the RKI stack gas. The results obtained from MS-CEM were compared with the material balance values. The system response time (including the MS-CEM) varies from 1.1 to 1.5 min.