• Title of article

    The sensitivity of room-air pulse oximetry in the detection of hypercapnia

  • Author/Authors

    Michael D. Witting، نويسنده , , Sam Hsu، نويسنده , , Carlos ، نويسنده , , res Granja، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2005
  • Pages
    4
  • From page
    497
  • To page
    500
  • Abstract
    Objective To estimate the sensitivity of room-air pulse oximetry in the detection of moderate hypercapnia. Methods In this retrospective case-control study, charts were reviewed from patients with and without moderate hypercapnia (Paco2 >50 mm Hg), as determined by analysis of arterial blood gas samples obtained in the ED. Test characteristics (sensitivity, specificity, and likelihood ratios [LR) for room-air pulse oximetry ≤96% to detect hypercapnia were calculated, as were confidence intervals. Results A total of 349 charts were eligible for abstraction—92 cases and 257 controls. A room-air pulse oximetry reading ≤96% detected 88 of 92 cases of hypercapnia. Test characteristics were as follows (with 95% confidence interval): sensitivity, 0.96 (0.89-0.99); specificity, 0.39 (0.33-0.45), LR of a room-air pulse oximetry value >96%, 0.1 (0.04-0.3); and LR of a room-air pulse oximetry value ≤96%, 1.6 (1.4-1.7). Conclusion Room-air pulse oximetry detects moderate hypercapnia with high sensitivity
  • Journal title
    American Journal of Emergency Medicine
  • Serial Year
    2005
  • Journal title
    American Journal of Emergency Medicine
  • Record number

    780732