Title of article :
Assessment of myocardial perfusion by myocardial contrast echocardiography using harmonic power and the transvenous contrast agent SHU 563A in acute coronary occlusion and after reperfusion
Author/Authors :
Claudius Teupe، نويسنده , , Masaaki Takeuchi، نويسنده , , Jiefen Yao، نويسنده , , Christopher Abadi، نويسنده , , Erick Avelar، نويسنده , , Thomas Fritzsch، نويسنده , , Natesa Pandian، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2001
Pages :
7
From page :
231
To page :
237
Abstract :
Background: Harmonic power Doppler imaging is a novel technique for the assessment of myocardial perfusion by contrast echocardiography. In this study, we examined whether myocardial contrast echocardiography using harmonic power Doppler and the new transvenous contrast agent SHU 563A can identify myocardial perfusion defects during coronary occlusion and reperfusion. Methods: To assess the potential of this technique, we occluded either the left anterior descending coronary artery or the circumflex coronary artery for 2 to 3 h followed by 1 h reperfusion in 10 dogs in an open chest model. After transvenous administration of SHU 563A, an air-filled, polymeric contrast agent, myocardial contrast echocardiography was performed in short and long axis views with triggered harmonic power Doppler imaging after coronary occlusion and reperfusion. Post-mortem triphenyl tetrazolium chloride staining was performed to verify infarction. Harmonic power Doppler and anatomic data were analyzed by independent observers. Results: During coronary occlusion, harmonic power Doppler showed perfusion defects in all 10 dogs. The defect size in the short axis view at papillary muscle level ranged 4–51% (14±13%) and 3–43% (16±10%) in the long axis view (% total LV slice area). After reperfusion (1 h) and infusion of dipyridamole (0.56 mg/kg), power Doppler demonstrated perfusion defects in seven dogs: 0–20% (9±8%) (short axis view) and 0–48% (13±14%) (long axis view). Five dogs showed anatomic infarction. The anatomic infarct area was 0–18% (6±8%) (slices corresponding to the echocardiographic short axis images). Perfusion defect size by harmonic power Doppler correlated well with residual infarct size (r=0.82, P<0.01). Conclusions: Myocardial contrast echocardiography using harmonic power Doppler and the new contrast agent SHU 563A accurately displays perfusion defects during acute coronary occlusion and after reperfusion. The site and size of residual myocardial infarction is reliably identified on line, in color. This approach has excellent potential for clinical application.
Keywords :
harmonic power Doppler , reperfusion , Occlusion , myocardial contrast echocardiography
Journal title :
International Journal of Cardiology
Serial Year :
2001
Journal title :
International Journal of Cardiology
Record number :
813338
Link To Document :
بازگشت