Title of article :
Successful aspiration of an LAD thrombus ‘cast’ using an Export catheter
Author/Authors :
T.A. Wells، نويسنده , , G. A. Whelan، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Abstract :
The use of a mechanical device to aspirate thrombus prior to stent deployment during primary angioplasty is currently not routinely recommended as results are often disappointing. However, we report a remarkable case during which we were able to successfully aspirate a 31 mm continuous length of thrombus using an Export catheter with subsequent dramatic improvement in both TIMI-flow and ST-segment resolution.
Keywords :
Export catheter , primary angioplasty , STEMI , thrombus
Journal title :
International Journal of Cardiology
Journal title :