• Title of article

    Efficiency, reproducibility and agreement of five different hemodynamic measures for optimization of cardiac resynchronization therapy

  • Author/Authors

    Zachary I. Whinnett، نويسنده , , Justin E.R. Davies، نويسنده , , Gemma Nott، نويسنده , , Keith Willson، نويسنده , , Charlotte H. Manisty، نويسنده , , Nicholas S. Peters، نويسنده , , Prapa Kanagaratnam، نويسنده , , D. Wyn Davies، نويسنده , , Alun D. Hughes، نويسنده , , Jamil Mayet، نويسنده , , Darrel P. Francis، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    11
  • From page
    216
  • To page
    226
  • Abstract
    Background Several hemodynamic measures have been used for optimization of the AV delay of cardiac resynchronization therapy (CRT), including pulse pressure (PP), systolic blood pressure (SBP) and cardiac output (CO). We aimed to determine whether these measures identify the same optimum and whether they have the same efficiency and reproducibility at identifying this optimum. Methods and results In 22 patients with cardiac resynchronization therapy, we adjusted the AV delay while atrially pacing at 110 bpm and simultaneously recording SBP, diastolic blood pressure (DBP), PP, mean arterial pressure (MAP) and CO. SBP, PP and CO all had essentially the same signal-to-noise ratios (15.4 ± 5.4, 15.5 ± 6.4, 15.3 ± 7.4 respectively p = NS). In contrast, MAP and DBP had significantly worse signal-to-noise ratios than SBP (14.2 ± 5.6, p = 0.003 and 12.1 ± 4.4, p < 0.0001 respectively). The optimal AV delay was very similar between SBP, PP, MAP and DBP. For example, the optima identified by SBP correlated strongly with those identified by PP (r = 0.94), MAP (r = 0.96) and DBP (r = 0.90). In contrast, the optima detected by CO was poorly related to these (e.g. r = 0.36 with SBP optima). Reproducibility was best for optima detected by SBP followed by MAP and PP. Conclusions Essentially the same AV optimum is identified, regardless of whether the parameter chosen for maximization is SBP, PP, MAP or DBP. We conclude that optimizing the CRT AV delay using SBP gives the best combination of efficiency and reproducibility, with PP and MAP being reasonable alternatives.
  • Keywords
    Atrioventricular delay optimization , cardiac resynchronization therapy , Hemodynamic optimization , Finometer
  • Journal title
    International Journal of Cardiology
  • Serial Year
    2008
  • Journal title
    International Journal of Cardiology
  • Record number

    816343